Evaluation of the exposure time of a Bulk-Fill resin in deep preparations

Authors

  • Eva Vásquez-Castro Faculty of Stomatology, Peruvian University Cayetano Heredia. Lima, Peru
  • José Portella-Atamari Faculty of Stomatology, Peruvian University Cayetano Heredia. Lima, Peru
  • Diego Melendez Faculty of Stomatology, Peruvian University Cayetano Heredia. Lima, Peru
  • Nicol Ramirez-Vilchez Faculty of Stomatology, Peruvian University Cayetano Heredia. Lima, Peru
  • Leyla Delgado-Cotrina Faculty of Stomatology, Peruvian University Cayetano Heredia. Lima, Peru

DOI:

https://doi.org/10.20453/reh.v32i1.4180

Keywords:

Hardness, time, composite resins, polymerization

Abstract

Background: Bulk-fill composite  resins  (BF)  are  used  in  posterior  restorations  with  extensive  and  deep preparations. One of the most outstanding benefits is that it can be used in increments of 4 to 5 mm, reducing clinical working time. However, in teeth with root canal treatment, these preparations could be deeper. Objectives: To determine the photoactivation time necessary to polymerize a Bulk-Fill resin located in deep areas. Material and Methods: In the present experimental in vitro study, specimens of Filtek One Bulk Fill composite resin (3M ESPE, St. Paul, USA) of 5x5x5 mm color A2 photoactivated at a distance/time of 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s and 3 mm/40 s (n=5) were fabricated. Surface microhardness was recorded on the surface and at the base of each specimen. Results: The highest microhardness value was recorded in group BF 0 mm/20 s and BF 3 mm/40 s (p<0.05), followed by groups BF 3 mm/20 s and BF 3 mm/30 s (p>0.05). The lowest microhardness values were found in the BF 0 mm/10 s and BF 3 mm/10 s groups. Conclusion: It takes 40 s of photoactivation to polymerize a Bulk-Fill resin located in deep areas, when the lamp is 3 mm away from the resin surface.

Downloads

Download data is not yet available.

References

Del Valle Rodríguez A,Christiani J, Álvarez N, Zamudio M. Revisión de resinas Bulk Fill: Estado actual. Rev Ateneo Argent Odontol. 2018; 58(1):55-60.

Kim RJ, Son SA, Hwang JY, Lee IB, Seo DG. Comparison of photopolymerization temperature increases in internal and external positions of composite and tooth cavities in real time: Incremental fillings of microhybrid composite vs. bulk filling of bulk fill composite. J. Dent. 2015;43(1):1093-1098.

Elshazly T, Bourauel C, Aboushelib M, Sherief D, El- Korashy D. The polymerization efficiency of a bulk- fill composite based on matrix-modification technology. Restor Dent Endod. 2020;45(3):1-12.

Yarmohammadi E, Kasraei Sh, Sadeghi Y. Comparative Assessment of Cuspal Deflection in Premolars Restored with Bulk-Fill and Conventional Composite Resins. Front Dent. 2019;16(6):407-414.

Almuallem L, McDonnell S, Bussuttil-Naudi A, Santini A. The effect of irradiation distance on light transmittance and vickers hardness ratio of two Bulk- fill resin-based composites. Eur J of Prosthodont Restor Dent. 2016; 24(4):203-214.

Tsuzuki FM, de Castro-Hoshino LV, Lopes LC, Sato F, Baesso ML, Terada RS. Evaluation of the influence of light-curing units on the degree of conversion in depth of a bulk-fill resin. J Clin Exp Dent. 2020;12(12):1117- 1123.

Ilie N, Luca B. Efficacy of modern light curing units in polymerizing peripheral zones in simulated large Bulk- fill Resin-composite Fillings. Oper Dent. 2018; 43(4):416-425.

Colombo M, Gallo S, Poggio C, Ricaldone V, Arciola C, Scribante A. New Resin-Based Bulk-Fill Composites: in vitro Evaluation of Micro-Hardness and Depth of Cure as Infection Risk Indexes. Mater. 2020;13(6):1-13.

Ide k, Nakajima M, Hayashi J, et al. Effect of light- curing time on light-cure/post-cure volumetric polymerization shrinkage and regional ultimate tensile strength at different depths of bulk-fill resin composites. Dent Mater J. 2019;38(4):621-629.

Alkhudhairy F. The effects of irradiance and exposure time on the surface roughness of bulk-fill composite resin restorative materials. Saudi Med J.2018;39(2):197- 202. .

Leprince, J, Palin, W, Hadis, M, Devaux J, Leloup G. Progress in dimethacrylate-based dental composite technology and curing efficiency. Dent Mater.2013; 29(2):139-156.

Tarle Z, Attin T, Marovic D, Andermatt L, Ristic M, Tauböck T. Influence of irradiation time on subsurface degree of conversion and microhardness of high- viscosity bulk-fill resin composites. Clin Oral Invest. 2014;19(4):831-840.

Voltarelli FR, Dos Santos-Daroz CB, Alves MC, Peris AR, Marchi GM. Effectiveness of resin composite polymerization when cured at different depths and with different curing lights. Gen Dent. 2009;57(4):314-319.

Shimokawa C, Turbino M, Giannini M, Braga R, Price R. Effect of Curing Light and Exposure Time on the Polymerization of Bulk-Fill Resin-Based Composites in MolarTeeth.Oper Dent..2020;45(3):141- 155.

Par M, Repusic I, Skenderovic H, Sever E.K, Marovic D, Tarle Z. Real-time Light Transmittance Monitoring for Determining Polymerization Completeness of Conventional and Bulk Fill Dental Composites. Oper Dent. 2018; 43(1):19-31.

Al-Zain AO, Platt JA. Effect of light-curing distance and curing time on composite microflexural strength. Dent Mater J. 2021;40(1):202-208.

Galvão MR, Caldas SGFR, Bagnato VS, De Souza Rastelli AN, De Andrade MF. Evaluation of Degree of Conversion and Hardness of Dental Composites Photo- Activated with Different Light Guide Tips. Eur J Dent. 2013;7(1):86-93.

Comba A, Scotti N, Maravić T, et al. Vickers Hardness and Shrinkage Stress Evaluation of Low and High Viscosity Bulk-Fill Resin Composite. Polymers (Basel). 2020;12(7):14-77

Published

2022-04-22

How to Cite

1.
Vásquez-Castro E, Portella-Atamari J, Melendez D, Ramirez-Vilchez N, Delgado-Cotrina L. Evaluation of the exposure time of a Bulk-Fill resin in deep preparations. Rev Estomatol Herediana [Internet]. 2022 Apr. 22 [cited 2024 Dec. 22];32(1):30-5. Available from: http://44.198.254.164/index.php/REH/article/view/4180