Comparación de la penetración de tres selladores endodónticos en los túbulos dentinarios con microscopia electrónica de barrido
DOI:
https://doi.org/10.20453/reh.v34i2.5530Abstract
Objective: To compare in vitro, through the use of a scanning electron microscope, the penetration of three endodontics sealers: Based on epoxy resin AH Plus®, based on polydimethylsiloxane Roekoseal® and based on Calcium Hydroxide, Apexit Plus® in the dentinal tubules 3 and 7mm from the root apex with the lateral compaction technique in single-root inferior premolar pieces. Materials and Methods: In vitro study, 36 teeth were prepared and divided into three groups of 12 pieces each group. All the pieces were prepared and each group was filled with three different endodontic sealers. Subsequently, the pieces were cut transversely at 3 and 7 mm from the root apex; They were then prepared to be taken to the scanning electron microscope to observe the penetration of the sealers into the dentinal tubules. Results: The Anova test was used to compare the three groups and the Student's T test was used to evaluate the penetration of each of the sealers at 3 and 7 mm. The Post Hoc Tukey test was also performed to evaluate between the sealers groups. When comparing the three groups of endodontic sealers, greater penetration was found with the Roekoseal® sealer at 3mm with a statistically significant difference in the Anova test (p=0.04). When comparing each of the sealers at 3mm and 7mm, only significant differences were found (p=0.04) in AH Plus® showing better penetration at 7 mm compared to 3mm and when it was compared between the groups of sealers at both 3 and 7 mm there were no statistically significant differences.
Conclusions: The three sealers tested penetrated the dentinal tubules. At 3 mm, Roekoseal® sealant outperformed the other two sealants, and at 7 mm, there was no significant difference between them.
Downloads
References
De Bruyne MA, De Bruyne RJ, Rosiers L, De Moor RJ. Longitudinal study on microleakage of three root-end filling materials by the fluid transport method and by capillary flow porometry. Int Endod J 2005; 38:129-36.
Libonati A, Montemurro E, Roberto Nardi R. Percentage of Gutta-percha–filled Areas in canals obturated by 3 Different Techniques with and without the use of endodontic Sealer. J Endod 2018; 44:506–509.
Moradi S, Ghoddusi J, Forghani M. Evaluation of Dentinal Tubule Penetration after the Use of Dentin Bonding Agent as a Root Canal Sealer. J Endod 2009; 35:1563–1566.
Alsubait S, Albader S, Alajlan N. Comparison of the antibacterial activity of calcium silicate and epoxy resin-based endodontic sealers against Enterococcus faecalis biofilms: a confocal laser-scanning microscopy analysis. Odontology 2019; 107, 513–520.
Gutmann JL, Witherspoon DE. Obturation of the cleaned and shaped root canal System. In: Cohen S, Burns R, eds. Caminos de la pulpa, 8va edición. San Louis: Mosby; 2004: 293–364
Peters L, Wesselink P, Moorer W. The fate and role of bacteria left in root dentinal tubules. Int Endod J 1995; 28: 95-99
Grossman L. An improved root canal cement. J. Am. Dent. Assoc 1958; 56:381-85.
Lioni B. Agentes selladores. Relación entre la velocidad de reabsorción y la bicompatibilidad. Electronic Journal Endodontics Rosario [Internet]. 2010 [citado mayo 2018]; 2: 462-485. Disponible en: https://rephip.unr.edu.ar/bitstream/handle/2133/1695/76-177-1-pb.pdf?sequence=1.
Zhang K, Kyung Kim Y, Cadenero M, Bryan T, Sidow S, et al. Efectts of different exposure times and concentrations of sodium hipoclorite / ethylendiaminetetraacetetic aci on the structura integrity of mineralizados dentin. J Endod 2010; 36: 105-9.
Ordinola - Zapata R, Bramante CM, Graeff MS, del Carpio Perochena A, Vivian RR, et al. Depth and percentage of penetration of endodontic sealers into dentinal tubules after root canal obturation using a lateral compaction technique: a confocal laser scanning microscopy study. Oral Surg Oral Medicine Oral Pathol Oral Radiol and Endod 2009; 108: 450-57.
Balguerie E, Van der Sluis L, Vallaeys K, Gurgel-Georgelin M, Diemer F. Sealer Penetration and Adaptation in the Dentinal Tubules: A Scanning Electron Microscopic Study. J Endod 2011; 37: 1576-79.
Kokkas A, Boutsioukis A, Vassiliadis P. The influencie of the Smear layer on dentinal tubule penetration depth by three Different Root canal sealers: An in vitro study. J Endod 2004; 2:100-2.
Sellador Roekoseal automix.[internet] [consultado agosto 2019] Disponible https://lam.coltene.com/es/
Siqueira J, Favieri A, Gahyva S, Moraes S, Lima K, Lopes H. Antimicrobial activity and flow rate of newer and established root canal sealers. J Endod. 2000; 26:274-77.
Bassem M, Ahmed S, Princy P, et al. scanning electron microscope Evaluation of dentinal tubules penetration of three different root Canal Sealers. EC Dental Science 2019; 18:1121-27
Carrigan P, Morse D, Furst L. A scanning electron microscopic evaluation of human dentinal tubules according to age and location. J Endod 1984; 10: 359-63
Khader AM. An in vitro scanning electron microscopy study to evaluate the dentinal tubular penetration depth of three root canal sealers. J Int Oral Health 2016; 8:191-94.
Van Meerbeek B, Vargas M, Inoue S, Yoshida Y, Perdigäo J, Lambrechts P, et al. Microscopy investigations. Techniques, results, limitations. Am J Dent 2000; 13: 3-18.
Mamootil K, Messer H. Penetration of dentinal tubules by endodontic sealer cements in extracted teeth and in vivo. Int Endod J 2007; 40: 873 – 81.
Oksan T, Aktener BO, Sen BH, Tezel H. The penetration of root canal sealers into dentinal tubules. A scanning electron microscopic study. Int Endod J 1993; 26:301– 05.
Bernardes RA, de Amorim Campelo A, Junior DSS, et al. Evaluation of the flow rate of 3 endodontic sealers: Sealer 26, AH Plus, and MTA Obtura. Oral Surgery, Oral Med Oral Pathol Oral Radiol Endod 2010; 109: 47-49.
Zhou Hui-min, Shen Y, Zheng W, Zheng YF, Haapasalo M. Physical properties of 5 root canal sealers. J Endod 2013;39: 1821-26.
Kont CF, Adanir N, Belli S, Pashley DH. A quantitative Evaluation Of apical leakage of four root canal sealers. Int Endod J 2002; 35:979-984.
Canalda C, Brau E. Endodoncia técnicas clínicas y bases científicas. 2da edición. Madrid: Masson;2006.
Faira NB, Massi S, Croti HR, Gutierrez JC. Comparative assessment of the flow rate of root canal sealers. Rev odonto cienc 2010; 25:170-173.
Chandra SS, Shankar P, Indira R. Depth of penetration of four resin sealers into radicular dentinal tubules: A confocal microscopic study. J Endod 2012; 38:1412-16.
Teixeira CS, Felippe MC, Felippe WT. The effect of application time of EDTA and NaOCl on intracanal smear layer removal: An SEM analysis. Int Endod J 2005; 38:285-90.
Paque F, Luder HU, Sener B, Zehnder M. Tubular sclerosis rather than the smear layer impedes dye penetration into the dentine of endodontically instrumented root canals. Int Endod J 2006; 39:18–25
Kwak S, Koo J, Gambarini G, Kim Hyeon-Cheol. Physicochemical Properties and biocompatibility of various Bioceramic Root Canal Sealers: In Vitro Study (J Endod 2023; 49:871–879
Versiani MA, Carvalho-Junior JR, Padilha MI, Lacey S, Pascon EA, Sousa-Neto MD. A comparative study of physicochemical properties of AH Plus and Epiphany root canal sealants. Int Endod J 2006; 39:464-71.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Revista Estomatológica Herediana
This work is licensed under a Creative Commons Attribution 4.0 International License.
The authors retain the copyright and cede to the journal the right of first publication, with the work registered with the Creative Commons License, which allows third parties to use what is published as long as they mention the authorship of the work, and to the first publication in this journal.